MedLine Excellence

AVE-733A Urine Analyzer

REFERENCE ID: 5821479630
The AVE-733A is a high-speed, compact benchtop urine analyzer designed for laboratories requiring efficiency and rapid "on-the-spot" results. Utilizing advanced Reflectance Photometric technology, it is capable of processing up to 514 tests per hour with exceptional accuracy. The system analyzes 14 dry chemistry parameters, including Microalbumin, Creatinine, and Calcium, and automatically calculates the ACR (Albumin/Creatinine Ratio) for early kidney disease screening. Features include a user-friendly touchscreen interface, built-in thermal printer, and strong anti-interference capability to correct for non-specific sample variations. \n \nDiaLine is an authorized distributor for Europe for this product. https://c-ave.eu/
Brand AVE
Availability By Request

Detailed Information






Testing items








 Dry Chemistry Items:

  • Blood (BLD)

  • Leukocytes (LEU)

  • Specific Gravity (SG)

  • pH

  • Glucose (GLU)

  • Protein (PRO)

  • Nitrites (NIT)

  • Ketones (KET)

  • Urobilinogen (URO)

  • Bilirubin (BIL)

  • Ascorbic Acid (VC)

  • Microalbumin (mALB)

  • Creatinine (CR)

  • Calcium Ions (Ca)

  • Can report Urine Microalbumin/Creatinine Ratio (ACR)









Detection Principle







Reflectance Photometric Colorimetric Method
The Reflectance Photometric Colorimetric Method is a technique used to measure the color and concentration of substances based on their light reflectance properties. It works by shining light onto a sample and analyzing the reflected wavelengths to determine its composition. This method is widely used in clinical diagnostics, environmental testing, and material analysis, as it provides precise colorimetric measurements without direct contact with the sample. It relies on photometers and colorimeters, which use filters to isolate specific wavelengths and detect variations in light intensity.














Product Features









Instant and Quick







Compact and flexible design makes the device ideal for on-the-spot testing as samples arrive.

Capable of continuous testing with high-speed processing, ensuring efficient and rapid results.







Convenient Operation







Touchscreen LCD display provides intuitive operation and clear visibility, enhancing user experience.

Flexible human-machine interaction allows for seamless control, adapting to various operational needs.







Accurate and Reliable





Strong anti-interference capability ensures accurate test results by automatically correcting for non-specific effects of test strips, pH values, specific gravity, and color.






Automatic Reporting







Automatic test result recognition ensures efficient processing and real-time reporting.

Supports thermal printers and external printers, enabling instant report output for seamless documentation.







Comprehensive Quality Control







Complete quality control system, ensuring high testing accuracy.

Equipped with original manufacturer-supplied test strips and quality control materials, maintaining consistent diagnostic reliability.

















Specification















































































Testing Criteria Performance Evaluation



Throughput







≤514 tests/hour







Test Strips







10-14 parameters optional







Repeatability







test result CV ≤1%







Accuracy







the difference between test results and target values is no more than one level;
no false negative result when tested with positive reference solution and no false positive result when tested with negative reference solution







Stability







test result CV ≤1% with power on of 8 hours







Printing







built-in thermal printers, external printer (optional)







Barcode Reader







external barcode reader (optional)







Storage







≥100000 test results







Relative Humidity







30% – 80%







Working Temperature







5°C – 40°C







Working Voltage







AC 100-240V, 50Hz







Power







100-240V – 50/60Hz, 250VA







Dimensions







380mm x 320mm x 190mm







Weight







4.5 kg











Recommended For

Hospital, Hospital\, Private laboratory\, Life Science, Life Science, Private laboratory